TIDMKMK

Kromek Group PLC

03 December 2020

This is an RNS Reach announcement and the information contained is not considered to be material or to have a significant impact on management's expectations of the Group's performance. RNS Reach is an investor communication service aimed at assisting listed and unlisted (including AIM quoted) companies to distribute non-regulatory news releases into the public domain. Information required to be notified under the AIM Rules for Companies, Market Abuse Regulation or other regulation would be disseminated as an RNS regulatory announcement and not on RNS Reach.

3 December 2020

Kromek Group plc

("Kromek" or the "Group")

Kromek launches the D5 RIID high performance radiation detector

World's smallest RIID with high accuracy and ultra-low false alarm rate

Kromek (AIM: KMK), a worldwide supplier of detection technology focusing on the medical, security screening and nuclear markets, announces the launch of the D5 RIID, the world's smallest high performance radioisotope identification device ("RIID"). The ruggedised device, with ultra-low false alarm rate, is designed for military, homeland security and industrial use.

The D5 RIID was developed under a programme with the Defense Threat Reduction Agency of the US Department of Defense. It detects a wide range of sources, including special nuclear material and mixed, shielded and heavily masked configurations. It provides high accuracy dose measurement and has an industry-leading ultra-low false alarm rate of less than 1 in 24 hours. The D5 RIID combines this advanced performance with being small, lightweight and easy-to-use - capable of being operated in one hand. It can also be used when wearing all levels of PPE, including gloves. It offers multiple modes of configuration, including being able to provide app-based training, and can be easily integrated into standard and custom networks.

It is the first device to be launched in Kromek's new D5 product range, which expands the Group's radiation detection portfolio to encompass devices specifically designed for more challenging use cases and harsh environments. This next-generation of product has a larger crystal, which enables higher accuracy and sensitivity - capable of detecting mixed, shielded and heavily masked configurations including special nuclear material - as well as being ruggedised.

Dr Arnab Basu, CEO of Kromek, said: "We are delighted to have launched the D5 RIID, which truly sets a new benchmark in radioisotope identification. The level of accuracy, combined with small size, far exceeds competing military standard detectors, enabling the rapid identification of radiological threats. As the first of our new D5 range, this device expands our portfolio to provide products ideal for use in harsh environments and for more challenging applications alongside our existing D3 solutions that are aimed at fleet deployment for large-scale networking across urban areas. We are proud to be continuing to drive innovation in this crucial area to enable rapid, informed decisions to be made in response to a radiation threat wherever it may appear."

For further information on the D5 RIID, please visit: https://www.kromek.com/product/d5-riid/

D5 RIID Detector Specification

 
 Detector type                CLLBC - Gamma and Neutron detection 
 Detector size                1.5" diameter x 1.5" long 
                             ---------------------------------------- 
 Gamma energy range           30 keV to 3 MeV 
                             ---------------------------------------- 
 Gamma dose rate range        0.01 uSv/h (10 uR/h) to 100 uSv/h (10 
                               mR/h) spectroscopic 
                               100 uSv/h (10 mR/h) to 1 Sv/h (100 
                               R/h) high dose sensor 
                             ---------------------------------------- 
 Dose accuracy                +/- 10% for Cs137 
                             ---------------------------------------- 
 Gamma resolution             Typically 3.5% @ 662 keV 
                             ---------------------------------------- 
 Area efficiency*             1.62 relative to a 2" x 2" Ø Nal 
                             ---------------------------------------- 
 Neutron sensitivity          𝐴𝜖𝑡= 16cm(2) 
                             ---------------------------------------- 
 Neutron detector gamma       Better than 10(-7) meets ANSI N42.34 
  rejection                    (2015) section 6.7 
                             ---------------------------------------- 
 Operational temperature      -20degC to 50degC 
  range 
                             ---------------------------------------- 
 Humidity                     Up to 93% RH 
                             ---------------------------------------- 
 Moisture/dust                IP67 
                             ---------------------------------------- 
 Batteries                    Primary cells: 2 x AA field replaceable 
                               Internal rechargeable: Li-Ion >2.25 
                               Ah 
                             ---------------------------------------- 
 Battery capacity (primary    24 hours at normal background 
  cells) 
                             ---------------------------------------- 
 Battery charging             1 hour to 50% capacity, 4 hours to 
                               full charge 
                             ---------------------------------------- 
 Wired interface              USB-C 
                             ---------------------------------------- 
 Wireless interface           Bluetooth 
                               Wi-Fi 802.11a/b/c/g/n 
                             ---------------------------------------- 
 Firmware updating            Update over USB 
                             ---------------------------------------- 
 Display                      2.8" colour antiglare with backlight 
                               suitable for both high and low light 
                             ---------------------------------------- 
 LED                          Three colour 
                             ---------------------------------------- 
 Alarm notifications          Visual, audio and vibration 
                             ---------------------------------------- 
 Device size                  173.1mm x 79mm x 41.1mm 
                             ---------------------------------------- 
 Device weight                660 g (1.47 lb) 
                             ---------------------------------------- 
 File storage                 ANSI N42.42 
                             ---------------------------------------- 
 Confirmation mode            30 sec to 5 minutes 
                             ---------------------------------------- 
 False alarm rate             Better than ANSI N42.34 (2015) 
                             ---------------------------------------- 
 Isotope ID                   ANSI N42.34 (2015) 
                             ---------------------------------------- 
 Hardware compliance          ANSI N42.34 (2015) 
                             ---------------------------------------- 
 Rugged military standard     MIL-STD-810Gm w/Charge 1 
  compliance 
                             ---------------------------------------- 
 Calibration stabilisation    Sourceless natural atmospheric 
                             ---------------------------------------- 
 

* Area efficiency = A (662 keV) /R(662) (keV) 1.5

For further information, please contact:

 
 Kromek Group plc 
 Arnab Basu, CEO 
  Paul Farquhar, CFO      +44 (0)1740 626 060 
 Luther Pendragon (PR) 
 Harry Chathli 
  Claire Norbury 
  Alexis Gore 
  Joe Quinlan             +44 (0)20 7618 9100 
 

About Kromek Group plc

Kromek Group plc is a technology group (global HQ in County Durham) and a leading developer of high performance radiation detection products based on cadmium zinc telluride ("CZT") and other advanced technologies. Using its core technology platforms, Kromek designs, develops and produces x-ray and gamma ray imaging and radiation detection products for the medical, security screening and nuclear markets.

The Group's products provide high resolution information on material composition and structure and are used in multiple applications, ranging from the identification of cancerous tissues to hazardous materials, such as explosives, and the analysis of radioactive materials.

The Group's business model provides a vertically integrated technology offering to customers, from radiation detector materials to finished products or detectors, including software, electronics and application specific integrated circuits ("ASICs").

The Group has operations in the UK and US (California and Pennsylvania), and is selling internationally through a combination of distributors and direct OEM sales.

Currently, the Group has over one hundred full-time employees across its global operations. Further information on Kromek Group is available at www.kromek.com and

https://twitter.com/kromekgroup.

This information is provided by Reach, the non-regulatory press release distribution service of RNS, part of the London Stock Exchange. Terms and conditions relating to the use and distribution of this information may apply. For further information, please contact rns@lseg.com or visit www.rns.com.

RNS may use your IP address to confirm compliance with the terms and conditions, to analyse how you engage with the information contained in this communication, and to share such analysis on an anonymised basis with others as part of our commercial services. For further information about how RNS and the London Stock Exchange use the personal data you provide us, please see our Privacy Policy.

END

NRAKKBBNKBDBOBK

(END) Dow Jones Newswires

December 03, 2020 02:00 ET (07:00 GMT)

Kromek (LSE:KMK)
Historical Stock Chart
From Jun 2024 to Jul 2024 Click Here for more Kromek Charts.
Kromek (LSE:KMK)
Historical Stock Chart
From Jul 2023 to Jul 2024 Click Here for more Kromek Charts.