TORONTO, Nov. 26, 2020 /CNW/ - Talisker Resources Ltd.
("Talisker" or the "Company") (TSX: TSK) (OTCQX: TSKFF) is pleased
to announce assay results from holes SB-2020-010, SB-2020-017A,
SB-2020-107AW1, SB-2020-018 and SB-2020-019 from its ongoing drill
program at the Bralorne Gold Project in British Columbia.
Key Points:
- Latest results confirm structural continuity of the 51, 52, 53,
55, 55 Splay, 55HW, 79 vein targets.
- Total of 25 vein targets validated (on 10 historical veins) and
three new vein discoveries confirmed in 2020 program, four
additional vein targets to be validated by end of 2020.
- Multiple intercepts further confirm the recently discovered,
close to surface Charlotte (four intercepts).
- Drilling intersected another broad zone of gold mineralization
(Knight Zone).
- 18,750m of 23,000m 2020 program completed, 6,870 samples
currently at assay lab.
- Resource drilling initiated on Charlotte Zone, planning for
2021 resource program nearing completion.
To date, Talisker has completed 18,750 metre of its current
23,000 metre drill program, results of which continue to verify and
prioritize the interpreted expansion and continuity of targeted
vein corridors. A further 6,879 core samples are currently at the
laboratory pending release. Today's results are highlighted
by a bonanza-grade intersection of 995 g/t gold over 0.5m from the 79 vein (Figures 1, 2, 3). Since
initiating drilling in February 2020,
exploration has focused on verification of the continuity of
high-grade gold-bearing vein targets developed from historic drift
samples and level plans.
Highlights include:
- SB-2020-019
-
- 995 g/t gold over 0.5m from
1,196.85m to 1,197.35m within 227.55 g/t gold over
2.25m
- SB-2020-010
-
- 12.75 g/t gold over 0.6m from
688.80m to 689.40m
- SB-2020-017A
-
- 13.05 g/t gold over 0.5m from
478.00m to 478.5m
- SB-2020-017AW1
-
- 62.70 g/t gold over 0.6m from
730.6m to 731.20m
- 16.15 g/t gold over 0.5m from
754.45m to 754.95m
Terry Harbort, President and CEO
of Talisker commented, "We are very pleased with today's
results that clearly highlight the high-grade nature of the
Bralorne Gold Project and continue to confirm our geological
model, the accuracy of our targeting system and the extensive
structural continuity of the veins. Together with the progress we
have made validating the historic database we can now implement our
planned 2021 resource definition drill program with
confidence."
Results were also received for the Charlotte Zone, an extensive
near-surface gold-bearing zone of quartz veining and brecciation.
The Charlotte zone represents broader, lower-grade style of gold
mineralization not previously recognised at Bralorne. More drilling
is required to determine the potential for near-surface bulk mining
potential at Charlotte and other near surface zones recently
identified.
Highlights from the Charlotte Zone include:
- SB-2020-019
-
- 1.37 g/t gold over 5.05m from
185.30m to 190.35m
- 3.73 g/t gold over 3.10m from
201.65m to 204.75m
- 4.04 g/t gold over 2.3m from
207.00m to 209.35m
Leonardo De Souza, Talisker's
Vice President, Exploration and Resource Development
added, "We are encouraged by the continuing development of the
Charlotte Zone and the discovery of a similar style of
mineralisation observed at the new Knight Zone. More drilling will
be required to determine the potential for near-surface bulk mining
potential at Charlotte and the other near surface zones recently
identified."
The transition to resource definition drilling coincides with
the mobilization of two additional drill rigs (announced
October 19, 2020), the installation
of additional office space and accommodation and the preparation of
the first 10 drill pads. The four drill rigs at site will focus on
delineating quartz vein-hosted gold mineralization to a depth of
~700m from surface, using a combination of current and historical
drillhole data and underground drift samples for drill
targeting.
Hole Details
SB-2020-019 Partial results received from rush assay
preparation. Three intercepts of the Charlotte Zone achieved at
shallow depths including composite sample value of 1.37 g/t Au over
5.05m from 185.30m to 190.35m,
composite sample value of 3.73 g/t over 3.10m from 201.65m
to 204.75m and composite value of
4.04 g/t Au over 2.30m from
207.00m to 209.35m. Vein 79 was intercepted as targeted
between 1,196.85m and 1,197.35m producing a high assay value of 995 g/t
Au over 0.5m from a sample of quartz
vein hosting visible gold and occurs within a broader (uncapped)
halo of 227.55 g/t gold over 2.25m
from 1,196.85m to 1,199.10m. Preliminary capping of this
sample at 100 g/t and compositing with proximal assays up to 12.05
g/t Au produces a composite value of 28.66 g/t Au over 2.25m. Screen metallic assay results of this
high-grade sample are currently pending. Further results from
SB-2020-019 are currently pending.
SB-2020-018 Partial results received from rush assay
preparation. An unknown vein was intercepted from 1,216.75m to 1,217.35m and produced 6.53 g/t Au over
0.65m within a larger zone of
mineralization which composites to 4.08 g/t Au over 1.25m. The 52 Vein target was intercepted as
planned at 1,233.6m to 1,234.85m and produced a composite value of 4.24
g/t Au over 1.25m. Further results
are pending.
SB-2020-017A intercepted an unknown vein zone with highlights of
9.37 g/t Au over 0.55m from
456m to 456.55m, 13.05 g/t Au over 0.50m from 478.00m
to 478.50m, and 3.69 g/t Au over
0.70m from 502.30m to 503m.
The zone is characterized by variable veining, strong alteration,
and shallow to core axis angle fault gouge planes. The 55 HW
vein was intercepted as planned at 704.50m to 705.15m
and produced 5.33 g/t Au over 0.65m.
The 55 Vein was intercepted as planned at 739.20m to 739.70m
and produced 8.13 g/t Au over 0.5m
within a broader zone of 4.08 g/t Au over 4.2m. The 53 Vein target was intercepted as
planned at 922.0m to 924.2m and produced a composite grade of 3.06 g/t
over 2.2m.
SB-2020-017AW1 was drilled as a wedge hole from hole 17A from
beginning at 425m downhole. At
730.6m to 731.20m a vein bearing shear structure associated
with the 55 Vein produced 62.7 g/t Au over 0.60m. At 754.45m
to 754.95m the 55 Vein produced 16.15
g/t Au over 0.50m.
SB-2020-017 was drilled to a depth of 215.20m before it was abandoned due to excessive
deviation. No significant results were produced. This hole was
re-started as SB-2020-017A.
SB-2020-016 was drilled to 255.8m
where it was determined to be off-course for deeper targets. No
significant intercepts were observed in hole 16. This hole
was re-started as SB-2020-016A.
SB-2020-016A was drilled to a final depth of 1,040.50m on September 5,
2020. Complete assays from this hole have been received.
Bralorne Gold
Project
Drill Holes
SB-2020-010, 017A, 017AW1, 018, 019
|
Diamond Drill
Hole Name
|
From
(m)
|
To
(m)
|
Interval
(m)
|
Au
g/t
|
Interpreted
Structure
|
Method
Reported
|
SB-2020-010
|
688.80
|
689.40
|
0.60
|
12.75
|
51 Vein
|
Au-SCR24
|
SB-2020-010
|
689.40
|
689.90
|
0.50
|
1.47
|
51 Vein
|
Au-AA24
|
SB-2020-010
|
689.90
|
690.40
|
0.50
|
2.06
|
51 Vein
|
Au-AA24
|
SB-2020-010
|
690.40
|
691.10
|
0.70
|
2.36
|
51 Vein
|
Au-AA24
|
|
|
|
|
|
|
|
SB-2020-017A
|
454.70
|
455.35
|
0.65
|
0.47
|
Knight
Zone
|
Au-AA24
|
SB-2020-017A
|
455.35
|
456.00
|
0.65
|
0.17
|
Knight
Zone
|
Au-AA24
|
SB-2020-017A
|
456.00
|
456.55
|
0.55
|
9.37
|
Knight
Zone
|
Au-SCR24
|
|
|
|
|
|
|
|
SB-2020-017A
|
478.00
|
478.50
|
0.50
|
13.05
|
Knight
Zone
|
Au-SCR24
|
|
|
|
|
|
|
|
SB-2020-017A
|
495.95
|
496.50
|
0.55
|
0.405
|
Knight
Zone
|
Au-AA24
|
SB-2020-017A
|
496.50
|
497.45
|
0.95
|
0.185
|
Knight
Zone
|
Au-AA24
|
SB-2020-017A
|
497.45
|
498.55
|
1.10
|
0.34
|
Knight
Zone
|
Au-AA24
|
SB-2020-017A
|
498.55
|
499.20
|
0.65
|
0.325
|
Knight
Zone
|
Au-AA24
|
SB-2020-017A
|
499.20
|
500.30
|
1.10
|
0.161
|
Knight
Zone
|
Au-AA24
|
SB-2020-017A
|
500.30
|
500.80
|
0.50
|
0.277
|
Knight
Zone
|
Au-AA24
|
SB-2020-017A
|
500.80
|
501.30
|
0.50
|
0.324
|
Knight
Zone
|
Au-AA24
|
SB-2020-017A
|
501.30
|
501.80
|
0.50
|
0.164
|
Knight
Zone
|
Au-AA24
|
SB-2020-017A
|
501.80
|
502.30
|
0.50
|
2.25
|
Knight
Zone
|
Au-AA24
|
SB-2020-017A
|
502.30
|
503.00
|
0.70
|
3.69
|
Knight
Zone
|
Au-SCR24
|
SB-2020-017A
|
503.00
|
503.75
|
0.75
|
0.597
|
Knight
Zone
|
Au-AA24
|
SB-2020-017A
|
503.75
|
504.25
|
0.50
|
0.145
|
Knight
Zone
|
Au-AA24
|
SB-2020-017A
|
504.25
|
504.85
|
0.60
|
1.405
|
Knight
Zone
|
Au-AA24
|
|
|
|
|
|
|
|
SB-2020-017A
|
699.70
|
700.35
|
0.65
|
2.80
|
55 HW Vein
|
Au-SCR24
|
SB-2020-017A
|
700.35
|
700.85
|
0.50
|
1.07
|
55 HW Vein
|
Au-AA24
|
SB-2020-017A
|
704.50
|
705.15
|
0.65
|
5.33
|
55 HW Vein
|
Au-SCR24
|
SB-2020-017A
|
705.15
|
705.65
|
0.50
|
0.64
|
55 HW Vein
|
Au-AA24
|
SB-2020-017A
|
708.95
|
709.50
|
0.55
|
2.54
|
55 HW Vein
|
Au-AA24
|
SB-2020-017A
|
709.50
|
710.00
|
0.50
|
3.89
|
55 HW Vein
|
Au-SCR24
|
|
|
|
|
|
|
|
SB-2020-017A
|
734.65
|
735.35
|
0.70
|
4.13
|
55 Vein
Splay
|
Au-SCR24
|
SB-2020-017A
|
737.10
|
737.60
|
0.50
|
2.31
|
55 Vein
|
Au-AA24
|
SB-2020-017A
|
737.60
|
738.25
|
0.65
|
5.00
|
55 Vein
|
Au-SCR24
|
SB-2020-017A
|
738.25
|
739.20
|
0.95
|
3.90
|
55 Vein
|
Au-SCR24
|
SB-2020-017A
|
739.20
|
739.70
|
0.50
|
8.13
|
55 Vein
|
Au-SCR24
|
SB-2020-017A
|
739.70
|
740.20
|
0.50
|
2.52
|
55 Vein
|
Au-AA24
|
SB-2020-017A
|
740.20
|
740.75
|
0.55
|
4.46
|
55 Vein
|
Au-SCR24
|
SB-2020-017A
|
740.75
|
741.30
|
0.55
|
2.26
|
55 Vein
|
Au-AA24
|
|
|
|
|
|
|
|
SB-2020-017A
|
921.10
|
922.00
|
0.90
|
1.03
|
53 Vein
|
Au-AA24
|
SB-2020-017A
|
922.00
|
923.00
|
1.00
|
3.22
|
53 Vein
|
Au-SCR24
|
SB-2020-017A
|
923.00
|
924.20
|
1.20
|
2.93
|
53 Vein
|
Au-AA24
|
|
|
|
|
|
|
|
SB-2020-017AW1
|
462.50
|
463.00
|
0.50
|
1.85
|
Knight
Zone
|
Au-AA24
|
SB-2020-017AW1
|
463.00
|
463.60
|
0.60
|
3.30
|
Knight
Zone
|
Au-AA24
|
SB-2020-017AW1
|
463.60
|
464.15
|
0.55
|
6.07
|
Knight
Zone
|
Au-AA24
|
SB-2020-017AW1
|
464.15
|
464.70
|
0.55
|
2.22
|
Knight
Zone
|
Au-AA24
|
SB-2020-017AW1
|
464.70
|
466.00
|
1.30
|
1.30
|
Knight
Zone
|
Au-AA24
|
|
|
|
|
|
|
|
SB-2020-017AW1
|
730.60
|
731.20
|
0.60
|
62.70
|
55 Vein
Splay
|
Au-GRA22
|
|
|
|
|
|
|
|
SB-2020-017AW1
|
753.90
|
754.45
|
0.55
|
2.64
|
55 Vein
|
Au-AA24
|
SB-2020-017AW1
|
754.45
|
754.95
|
0.50
|
16.15
|
55 Vein
|
Au-GRA22
|
SB-2020-017AW1
|
754.95
|
755.60
|
0.65
|
0.78
|
55 Vein
|
Au-AA24
|
|
|
|
|
|
|
|
SB-2020-018
|
1216.75
|
1217.40
|
0.65
|
6.53
|
52 Vein
Splay
|
Au-AA24
|
SB-2020-018
|
1217.40
|
1218.00
|
0.60
|
1.43
|
52 Vein
Splay
|
Au-AA24
|
|
|
|
|
|
|
|
SB-2020-018
|
1233.6
|
1234.2
|
0.6
|
4.58
|
52 Vein
|
Au-AA24
|
SB-2020-018
|
1234.2
|
1234.85
|
0.65
|
3.93
|
52 Vein
|
Au-AA24
|
SB-2020-018
|
1234.85
|
1235.5
|
0.65
|
0.47
|
52 Vein
|
Au-AA24
|
|
|
|
|
|
|
|
SB-2020-019
|
185.30
|
185.80
|
0.50
|
2.50
|
Charlotte
|
Au-AA24
|
SB-2020-019
|
185.80
|
186.45
|
0.65
|
2.41
|
Charlotte
|
Au-AA24
|
SB-2020-019
|
186.45
|
187.50
|
1.05
|
0.14
|
Charlotte
|
Au-AA24
|
SB-2020-019
|
187.50
|
188.10
|
0.60
|
0.45
|
Charlotte
|
Au-AA24
|
SB-2020-019
|
188.10
|
188.65
|
0.55
|
1.31
|
Charlotte
|
Au-AA24
|
SB-2020-019
|
188.65
|
189.45
|
0.80
|
0.17
|
Charlotte
|
Au-AA24
|
SB-2020-019
|
189.45
|
190.35
|
0.90
|
3.16
|
Charlotte
|
Au-AA24
|
|
|
|
|
|
|
|
SB-2020-019
|
201.65
|
202.20
|
0.55
|
8.91
|
Charlotte
|
Au-AA24
|
SB-2020-019
|
202.20
|
203.00
|
0.80
|
3.04
|
Charlotte
|
Au-AA24
|
SB-2020-019
|
203.00
|
203.55
|
0.55
|
5.12
|
Charlotte
|
Au-AA24
|
SB-2020-019
|
203.55
|
204.75
|
1.20
|
1.17
|
Charlotte
|
Au-AA24
|
SB-2020-019
|
204.75
|
205.25
|
0.50
|
0.08
|
Charlotte
|
Au-AA24
|
SB-2020-019
|
205.25
|
206.50
|
1.25
|
0.02
|
Charlotte
|
Au-AA24
|
SB-2020-019
|
206.50
|
207.00
|
0.50
|
1.49
|
Charlotte
|
Au-AA24
|
SB-2020-019
|
207.00
|
207.60
|
0.60
|
6.44
|
Charlotte
|
Au-AA24
|
SB-2020-019
|
207.60
|
208.10
|
0.50
|
4.09
|
Charlotte
|
Au-AA24
|
SB-2020-019
|
208.10
|
208.60
|
0.50
|
3.27
|
Charlotte
|
Au-AA24
|
SB-2020-019
|
208.60
|
209.30
|
0.70
|
2.50
|
Charlotte
|
Au-AA24
|
SB-2020-019
|
209.30
|
210.15
|
0.85
|
1.83
|
Charlotte
|
Au-AA24
|
SB-2020-019
|
210.15
|
211.00
|
0.85
|
1.85
|
Charlotte
|
Au-AA24
|
SB-2020-019
|
211.00
|
212.00
|
1.00
|
0.04
|
Charlotte
|
Au-AA24
|
SB-2020-019
|
212.00
|
213.50
|
1.50
|
0.07
|
Charlotte
|
Au-AA24
|
SB-2020-019
|
213.50
|
215.00
|
1.50
|
0.01
|
Charlotte
|
Au-AA24
|
SB-2020-019
|
215.00
|
216.00
|
1.00
|
0.00
|
Charlotte
|
Au-AA24
|
SB-2020-019
|
216.00
|
217.00
|
1.00
|
0.00
|
Charlotte
|
Au-AA24
|
SB-2020-019
|
217.00
|
217.55
|
0.55
|
0.03
|
Charlotte
|
Au-AA24
|
SB-2020-019
|
217.55
|
218.05
|
0.50
|
3.10
|
Charlotte
|
Au-AA24
|
SB-2020-019
|
218.05
|
218.60
|
0.55
|
0.11
|
Charlotte
|
Au-AA24
|
SB-2020-019
|
218.60
|
219.45
|
0.85
|
0.81
|
Charlotte
|
Au-AA24
|
SB-2020-019
|
219.45
|
220.20
|
0.75
|
1.37
|
Charlotte
|
Au-AA24
|
|
|
|
|
|
|
|
SB-2020-019
|
1017.25
|
1018.15
|
0.90
|
5.10
|
53 Vein
|
Au-AA24
|
SB-2020-019
|
1018.15
|
1018.65
|
0.50
|
2.97
|
53 Vein
|
Au-AA24
|
SB-2020-019
|
1020.40
|
1020.90
|
0.50
|
0.04
|
53 FW Vein
|
Au-AA24
|
SB-2020-019
|
1020.90
|
1021.50
|
0.60
|
0.15
|
53 FW Vein
|
Au-AA24
|
SB-2020-019
|
1021.50
|
1022.10
|
0.60
|
0.04
|
53 FW Vein
|
Au-AA24
|
SB-2020-019
|
1022.10
|
1022.60
|
0.50
|
3.86
|
53 FW Vein
|
Au-AA24
|
SB-2020-019
|
1022.60
|
1023.15
|
0.55
|
5.11
|
53 FW Vein
|
Au-AA24
|
SB-2020-019
|
1023.15
|
1023.65
|
0.50
|
2.87
|
53 FW Vein
|
Au-AA24
|
|
|
|
|
|
|
|
SB-2020-019
|
1196.85
|
1197.35
|
0.50
|
995.00
|
79 Vein
|
Au-GRA22
|
SB-2020-019
|
1197.35
|
1197.90
|
0.55
|
0.06
|
79 Vein
|
Au-AA24
|
SB-2020-019
|
1197.90
|
1199.10
|
1.20
|
12.05
|
79 Vein
|
Au-GRA22
|
Notes: Diamond drill
hole SB-2020-010 has collar orientation of Azimuth 176; Dip -58.
SB-2020-017A has collar orientation of
Azimuth 193; Dip -48. SB-2020-017AW1 has collar orientation of
Azimuth 193; Dip -48. Diamond drill hole SB-2020-018 has collar
orientation of Azimuth 153; Dip -56. SB-2020-019 has collar
orientation of Azimuth 193; Dip -55. True widths are estimated at
60
- 90% of intercept lengths and are based on oriented core
measurements where available. Method Reported includes the most
up
to date information as of the date of this press
release.
|
Talisker is providing an opportunity for shareholders and other
interested parties to participate in a Webinar to be held at
4 pm ET on Tuesday, December
1st. To register, please click on the following link -
https://us02web.zoom.us/webinar/register/WN_AsT2WWGyQ6Clv1wadUEBjQ.
After registering, you will receive a confirmation email containing
information about joining the webinar.
About Talisker Resources Ltd.
Talisker (taliskerresources.com) is a junior resource
company involved in the exploration of gold projects in
British Columbia, Canada.
Talisker's projects include the Bralorne Gold Complex, an advanced
stage project with significant exploration potential from a
historical high-grade producing gold mine as well as its Spences
Bridge Project where the Company holds ~85% of the emerging Spences
Bridge Gold Belt and several other early-stage Greenfields
projects. With its properties comprising 297,644 hectares over
331 claims, six leases and 198 crown grant claims,
Talisker is a dominant exploration player in the south-central
British Columbia. The Company is
well funded to advance its aggressive systematic exploration
program at its projects.
Qualified Person
The technical information contained in this news release
relating to the drill results at the Bralorne Gold Project has been
approved by Leonardo de Souza (BSc,
AusIMM (CP) Membership 224827), Talisker's Vice President,
Exploration and Resource Development, who is a "qualified person"
within the meaning of National Instrument 43-101, Standards of
Disclosure for Mineral Projects.
Sample Preparation and QAQC
Drill core at the Bralorne project is drilled in HQ to NQ size
ranges (63.5mm and 47.6mm respectively). Drill core samples are
minimum 50 cm and maximum 160 cm long along the core axis. Samples
are focused on an interval of interest such as a vein or zone of
mineralization. Shoulder samples bracket the interval of
interest such that a total sampled core length of not less than
3 m both above and below the interval
of interest must be assigned. Sample QAQC measures of unmarked
certified reference materials (CRMs), blanks, and duplicates are
inserted into the sample sequence and make up 9% of the samples
submitted to the lab for holes reported in this release.
Sample preparation and analyses is carried out by ALS Global, at
their laboratory in North Vancouver,
British Columbia, Canada. Drill core sample preparation
includes drying in an oven at a maximum temperature of 60°C, fine
crushing of the sample to at least 70% passing less than 2 mm,
sample splitting using a riffle splitter, and pulverizing a 250 g
split to at least 85% passing 75 microns (code PREP-31).
Gold and in diamond drill core is analysed by fire assay and
atomic absorption spectroscopy (AAS) of a 50g sample (code
Au-AA24), while multi-element chemistry is analysed by 4-Acid
digestion of a 0.25 g sample split with detection by inductively
coupled plasma mass spectrometer (ICP-MS) for 48 elements (Ag, Al,
As, Ba, Be, Bi, Ca, Cd, Ce, Co, Cr, Cs, Cu, Fe, Ga, Ge, Hf, In, K,
La, Li, Mg, Mn, Mo, Na, Nb, Ni, P, Pb, Rb, Re, S, Sb, Sc, Se, Sn,
Sr, Ta, Te, Th, Ti, Tl, U, V, W, Y, Zn, Zr).
Gold assay technique Au-AA24 has an upper detection limit of
10ppm. Any sample that produces an over-limit gold value via the
Au-AA24 technique is sent for gravimetric finish via method
Au-GRA22 which has an upper detection limit of 1,000 ppm Au.
Samples where visible gold was observed are sent directly to screen
metallics analysis and all samples that fire assay above 3 ppm Au
are re-analysed with method Au-SCR24
which employs a 1kg pulp screened to 100 microns with assay of the
entire oversize fraction and duplicate 50g assays on the undersize
fraction. Where possible all samples initially sent to screen
metallics processing will also be re-run through the fire assay
with gravimetric finish provided there is enough material left for
further processing.
Caution Regarding Forward Looking Statements
Certain statements contained in this press release constitute
forward-looking information. These statements relate to future
events or future performance. The use of any of the words "could",
"intend", "expect", "believe", "will", "projected", "estimated" and
similar expressions and statements relating to matters that are not
historical facts are intended to identify forward-looking
information and are based on Talisker's current belief or
assumptions as to the outcome and timing of such future events.
Actual future results may differ materially. In particular, this
release contains forward-looking information relating to, among
other things, the operations of the Company and the timing which
could be affected by the current global COVID-19 pandemic. Those
assumptions and factors are based on information currently
available to Talisker. Although such statements are based on
reasonable assumptions of Talisker's management, there can be no
assurance that any conclusions or forecasts will prove to be
accurate.
While Talisker considers these assumptions to be reasonable
based on information currently available, they may prove to be
incorrect. Forward looking information involves known and unknown
risks, uncertainties and other factors which may cause the actual
results, performance or achievements to be materially different
from any future results, performance or achievements expressed or
implied by the forward-looking information. Such factors include
risks inherent in the exploration and development of mineral
deposits, including risks relating to changes in project parameters
as plans continue to be redefined, risks relating to variations in
grade or recovery rates, risks relating to changes in mineral
prices and the worldwide demand for and supply of minerals, risks
related to increased competition and current global financial
conditions and the COVID-19 pandemic, access and supply risks,
reliance on key personnel, operational risks, and regulatory risks,
including risks relating to the acquisition of the necessary
licenses and permits, financing, capitalization and liquidity
risks.
The forward-looking information contained in this release is
made as of the date hereof, and Talisker is not obligated to update
or revise any forward-looking information, whether as a result of
new information, future events or otherwise, except as required by
applicable securities laws. Because of the risks, uncertainties and
assumptions contained herein, investors should not place undue
reliance on forward-looking information. The foregoing statements
expressly qualify any forward-looking information contained
herein.
Figure 1: Plan view of the Bralorne deposit showing the location
of drill holes included in this release, target veins/panels and
interpreted vein corridors (coloured zones), historic mine stopes
and historic drift samples.
Figure 2: Long section view of the Bralorne deposit showing the
location of drill holes included in this release, target
veins/panels and interpreted vein corridors (coloured zones),
historic mine stopes and historic drift samples.
Figure 3: Cross-section view of the Bralorne deposit showing the
location of drill holes included in this release, target
veins/panels and interpreted vein corridors (coloured zones),
historic mine stopes and historic drift samples.
SOURCE Talisker Resources Ltd