Recent drilling results confirm the continuity and growth
potential of FDNS as a new high-grade system across the south
of FDN
VANCOUVER, BC, Nov. 4, 2024
/CNW/ - Lundin Gold Inc. (TSX: LUG) (Nasdaq Stockholm: LUG)
(OTCQX: LUGDF) ("Lundin Gold" or the "Company") is
pleased to announce additional results from its ongoing 2024
near-mine and conversion drilling programs at its 100% owned Fruta
del Norte ("FDN") gold mine in southeast Ecuador. Recent drilling results at FDN South
("FDNS") confirm the continuity and the high-grade nature of this
mineralized system across the southern extension of the FDN
deposit. The conversion drilling program continued to return
high-grade results and confirm mineralization immediately adjacent
to mine workings. Highlights from the near mine program and
conversion program are outlined below. Detailed results are
provided at the end of this release (see Appendix 1). View PDF
FDNS Exploration Drilling Highlights (not true
widths):
- Drill hole UGE-S-24-145 intersected 22.67 grams per tonne
("g/t") of gold ("Au") over 41.60m
from 26.40m, including:
- 68.81 g/t Au over 4.70m
- 53.08 g/t Au over 10.80m
- Drill hole UGE-S-24-175 intersected 15.26 g/t Au over
37.95 m from 19.35 m, including:
- 65.01 g/t Au over 5.35 m
- 22.02 g/t Au over 4.30 m
- Drill hole UGE-S-24-174 intersected 9.02 g/t Au over
26.20 m from 4.60 m, including:
- 16.20 g/t Au over 12.10 m
Conversion Drilling Highlights (not true widths):
- Drill hole FDN-C24-140 intersected 8.28 g/t Au over
80.90 m from 143.50 m, including:
- Drill hole FDN-C24-157 intersected 7.00 g/t Au over
46.50 m from 5.00 m, including:
- 20.17 g/t Au over 10.35 m
- Drill hole FDN-C24-153 intersected 18.75 g/t Au over
10.90 m from 18.50 m, including:
Ron Hochstein, President and
CEO, commented, "I am very excited with our drilling programs at
the FDN deposit. These results demonstrate that the true potential
of FDN has yet to be fully discovered. At FDNS, delineation
drilling continues to confirm the continuity of a new high-grade
vein system with some of the best drill intercepts achieved to
date. In addition, conversion drilling has successfully concluded
for the year and has defined several wide, high-grade mineralized
zones that we expect to convert from Mineral Resources to Mineral
Reserves as part of our updated resource estimate planned to be
issued in the first quarter of next year. Both programs continue to
highlight a great potential for additional Mineral Reserves at
FDN."
NEAR-MINE EXPLORATION PROGRAM
The Company's near-mine exploration strategy focuses on
extending mine life through the expansion of Mineral Resources at
FDN by exploring and delineating new discoveries close to the
operation. Ten rigs are currently turning on the FDN near-mine
exploration program, three underground and seven on surface. A
total of 45,325 metres across 120 holes, from surface and
underground, has been completed to date in 2024 as part of the
near-mine program. Since the second quarter, the program has
concentrated on FDNS.
FDNS
At FDNS, the underground drilling program advanced along strike
and at depth, following up on the initial high-grade results in
this sector (see news release dated July
31, 2024) (Figure 1 and 2). Since the start of this
program in the second quarter, a total of 31 drill holes have been
completed, and the results have confirmed a high-grade vein system,
of distinct geometry and style when compared to the FDN deposit, in
a sector that had been previously defined as lower grade (Figure
2).
The recent drill holes, completed from underground levels 1170
and 1080, showed significant results associated with distinct
levels of hydrothermal alteration with chalcedony and
manganoan-calcite veins with sulfides and visible gold.
Intersections from drill holes UGE-S-24-145 (53.08 g/t Au
over 10.80m) and
UGE-S-24-175 (65.01 g/t Au over 5.35m), are some of the highest-grade
intercepts ever recorded in the sector. All the recent results are
being incorporated into a new geological model for this sector and
are expected to be part of the update to the FDN Mineral Resource
estimate to be completed in the first quarter of next year. Assay
results are presented in Tables 1 and 3 at the end of this release.
Results are still pending for some drill holes.
The recent drilling results also indicate the expansion
potential of this high-grade system at depth as well as south,
where additional drill holes from the recently reopened South
Portal should further provide opportunities to explore the
continuity. The South Portal was installed by the previous owner of
FDN, Kinross Gold Corporation. Over the past nine months 465 metres
of the 670 metre portal have been dewatered and rehabilitated, and
exploration drill platforms constructed. Two underground rigs are
currently turning at FDNS.
CONVERSION PROGRAM
The 2024 conversion drilling program was focused on converting
Inferred Mineral Resources to Indicated in areas immediately beyond
the current Mineral Reserve boundary in the north and central
sectors of the FDN deposit. A total of 13,755 metres of underground
drilling from 110 drill holes was executed in 2024, and drilling
for this year is now complete. All drill results to date have
significantly improved the Company's confidence in the geologic
model.
Numerous drill holes have confirmed wide and high-grade
intercepts associated with large hydrothermal alteration zones
represented by breccias, veining or stockwork zones, very similar
in style and geometry to that found in the areas of the north
sector currently being mined (see Figure 3). This year's conversion
drilling results are currently being incorporated into the
geological model and will form the basis of an updated Mineral
Resources and Reserves estimate to be completed during the first
quarter of 2025. Complete assay results received to date are
presented in Tables 2 and 3 at the end of this release. Some
results from the conversion program are pending.
Qualified Persons
The technical information contained in this News Release has
been reviewed and approved by Andre
Oliveira, P. Geo, Vice President, Exploration of the
Company, who is a Qualified Person in accordance with the
requirements of National Instrument 43-101 – Standards of
Disclosure for Mineral Projects.
Samples consist of half HQ and NQ-size diamond core that are
split by diamond saw on site, prepared at the ALS laboratory in
Quito, and analysed by 50g fire
assay and multi-element (ICP-AES/ICP-MS) at the ALS Laboratory in
Lima, Peru. The quality
assurance-quality control ("QA-QC") program of Lundin Gold includes the insertion of certified
standards of known gold content, blank and duplicate samples. The
remaining half core is retained for verification and reference
purposes. For further information on the assay, QA-QC and data
verification procedures, please see Lundin
Gold's Annual Information Form dated March 26, 2024, filed under the Company's profile
at www.sedarplus.ca.
About Lundin Gold
Lundin Gold, headquartered in
Vancouver, Canada, owns the Fruta
del Norte gold mine in southeast Ecuador. Fruta del Norte is among the
highest-grade operating gold mines in the world.
The Company's board and management team have extensive expertise
in mine operations and are dedicated to operating Fruta del Norte
responsibly. The Company operates with transparency and in
accordance with international best practices. Lundin Gold is committed to delivering value to
its shareholders, while simultaneously providing economic and
social benefits to impacted communities, fostering a healthy and
safe workplace and minimizing the environmental impact. The Company
believes that the value created through the development of Fruta
del Norte will benefit its shareholders, the Government and the
citizens of Ecuador.
Additional Information
The information in this release is subject to the disclosure
requirements of Lundin Gold under
the EU Market Abuse Regulation. This information was publicly
communicated on November 4, 2024 at
3:20 p.m. Pacific Time through the
contact persons set out below.
Caution Regarding Forward-Looking Information and
Statements
Certain of the information and statements in this press release
are considered "forward-looking information" or "forward-looking
statements" as those terms are defined under Canadian securities
laws (collectively referred to as "forward-looking statements").
Any statements that express or involve discussions with respect to
predictions, expectations, beliefs, plans, projections, objectives,
assumptions or future events or performance (often, but not always,
identified by words or phrases such as "believes", "anticipates",
"expects", "is expected", "scheduled", "estimates", "pending",
"intends", "plans", "forecasts", "targets", or "hopes", or
variations of such words and phrases or statements that certain
actions, events or results "may", "could", "would", "will",
"should" "might", "will be taken", or "occur" and similar
expressions) are not statements of historical fact and may be
forward-looking statements. By their nature, forward-looking
statements and information involve assumptions, inherent risks and
uncertainties, many of which are difficult to predict, and are
usually beyond the control of management, that could cause actual
results to be materially different from those expressed by these
forward-looking statements and information. Lundin
Gold believes that the expectations reflected in this
forward-looking information are reasonable, but no assurance can be
given that these expectations will prove to be correct.
Forward-looking information should not be unduly relied upon. This
information speaks only as of the date of this press release, and
the Company will not necessarily update this information, unless
required to do so by securities laws.
This press release contains forward-looking information in a
number of places, such as in statements relating to the Company's
exploration plans, activities and results and its plans to update
its estimates of Mineral Reserves and Resources. There can be no
assurance that such statements will prove to be accurate,
as Lundin Gold's actual results and future events could
differ materially from those anticipated in this forward-looking
information as a result of the factors discussed in the "Risk
Factors" section in Lundin Gold's Annual Information Form
dated March 26, 2004, which is
available at www.lundingold.com or www.sedarplus.ca.
Lundin Gold's actual results
could differ materially from those anticipated. Factors that could
cause actual results to differ materially from any forward-looking
statement or that could have a material impact on the Company or
the trading price of its shares include: instability in
Ecuador; community relations;
forecasts relating to production and costs; mining operations;
security; non-compliance with laws and regulations and compliance
costs; tax changes in Ecuador;
waste disposal and tailings; government or regulatory approvals;
environmental compliance; gold price; infrastructure; dependence on
a single mine; exploration and development; control of Lundin Gold; availability of workforce and
labour relations; dividends; information systems and cyber
security; Mineral Reserve and Mineral Resource estimates; title
matters and surface rights and access; health and safety; human
rights; employee misconduct; measures to protect biodiversity;
endangered species and critical habitats; global economic
conditions; shortages of critical resources; competition for new
projects; key talent recruitment and retention; market price of the
Company's shares; social media and reputation; insurance and
uninsured risks; pandemics, epidemics or infectious disease
outbreak; climate change; illegal mining; conflicts of interest;
ability to maintain obligations or comply with debt; violation of
anti-bribery and corruption laws; internal controls; claims and
legal proceedings; and reclamation obligations.
APPENDIX 1
Table 1: Drillhole assay results from the
near-mine drilling program at FDNS reported for thickness versus
grade intervals above 14 (m x g/t Au >14). Drill hole intercepts
are reported in drill core lengths
Hole
ID
|
From
(m)
|
To
(m)
|
Interval
(m)
|
Au
(g/t)
|
Ag
(g/t)
|
Target
|
Zone
|
UGE-S-24-135
|
7.0
|
10.9
|
3.9
|
3.39
|
7.14
|
FDNS
|
Underground
|
UGE-S-24-135
|
80.3
|
83.6
|
3.3
|
3.19
|
16.30
|
UGE-S-24-135
|
101.5
|
115
|
13.5
|
3.96
|
20.26
|
Including
|
102.5
|
105.8
|
3.3
|
8.74
|
52.19
|
UGE-S-24-135
|
124.4
|
143.8
|
19.4
|
2.15
|
17.63
|
UGE-S-24-135
|
149.8
|
165.6
|
15.8
|
3.35
|
12.44
|
UGE-S-24-139
|
6.0
|
10
|
4.0
|
5.12
|
6.43
|
FDNS
|
Underground
|
UGE-S-24-139
|
42.6
|
45.7
|
3.1
|
3.21
|
13.35
|
UGE-S-24-139
|
64
|
70.3
|
6.3
|
8.45
|
46.36
|
Including
|
65.8
|
67.9
|
2.1
|
22.31
|
78.85
|
UGE-S-24-139
|
83.1
|
87.4
|
4.3
|
3.24
|
15.75
|
UGE-S-24-139
|
94.2
|
96.6
|
2.4
|
8.73
|
27.75
|
UGE-S-24-139
|
139.1
|
143.3
|
4.2
|
3.21
|
12.95
|
UGE-S-24-142
|
0
|
6.1
|
6.1
|
5.79
|
4.62
|
FDNS
|
Underground
|
UGE-S-24-142
|
52.9
|
55.7
|
2.8
|
8.65
|
10.79
|
UGE-S-24-142
|
61
|
75.8
|
14.8
|
7.59
|
15.63
|
Including
|
72.8
|
76.8
|
4.0
|
19.42
|
26.66
|
UGE-S-24-142
|
91.6
|
104.1
|
12.5
|
2.90
|
60.42
|
Including
|
91.6
|
96
|
4.4
|
3.95
|
35.62
|
UGE-S-24-142
|
118.7
|
128.7
|
10
|
5.86
|
32.31
|
Including
|
121.6
|
125.5
|
3.9
|
12.68
|
48.50
|
UGE-S-24-142
|
193.3
|
197.3
|
4.0
|
2.11
|
12.50
|
UGE-S-24-145
|
7.9
|
12.3
|
4.4
|
4.73
|
20.28
|
FDNS
|
Underground
|
UGE-S-24-145
|
26.4
|
68
|
41.6
|
22.67
|
15.88
|
Including
|
40.7
|
45.4
|
4.7
|
68.81
|
34.89
|
Including
|
57.2
|
68
|
10.8
|
53.08
|
26.49
|
UGE-S-24-145
|
81.7
|
106.8
|
25.1
|
3.92
|
8.80
|
Including
|
90.2
|
98.4
|
8.2
|
6.39
|
10.83
|
UGE-S-24-150
|
45.6
|
49.1
|
3.5
|
3.83
|
3.72
|
FDNS
|
Underground
|
UGE-S-24-150
|
70.8
|
75.3
|
4.5
|
2.98
|
5.59
|
UGE-S-24-150
|
106.9
|
131.1
|
24.2
|
4.46
|
8.48
|
Including
|
121.3
|
124.9
|
3.6
|
16.27
|
12.73
|
UGE-S-24-150
|
141
|
154.8
|
13.8
|
6.85
|
11.20
|
Including
|
143.8
|
150
|
6.2
|
12.01
|
15.86
|
UGE-S-24-152
|
0.4
|
7.3
|
6.9
|
4.67
|
4.86
|
FDNS
|
Underground
|
UGE-S-24-152
|
127.9
|
132.8
|
4.9
|
5.08
|
8.59
|
UGE-S-24-153
|
106.4
|
110.4
|
4
|
8.44
|
2.58
|
FDNS
|
Underground
|
UGE-S-24-153
|
146.2
|
153.3
|
7.1
|
9.71
|
2.30
|
UGE-S-24-155
|
78.15
|
81.15
|
3
|
8.91
|
3.47
|
FDNS
|
Underground
|
UGE-S-24-155
|
122.2
|
139.1
|
16.9
|
6.31
|
1.38
|
Including
|
133.1
|
139.1
|
6
|
8.66
|
1.69
|
UGE-S-24-155
|
156.55
|
159.95
|
3.4
|
6.56
|
1.15
|
UGE-S-24-155
|
174.3
|
178.1
|
3.8
|
8.85
|
1.22
|
UGE-S-24-158
|
125.3
|
129.3
|
4
|
4.34
|
9.76
|
FDNS
|
Underground
|
UGE-S-24-158
|
136.7
|
140.7
|
4
|
3.88
|
2.14
|
UGE-S-24-158
|
153.2
|
157.8
|
4.6
|
8.08
|
1.73
|
UGE-S-24-159
|
Pending
Results
|
FDNS
|
Underground
|
UGE-S-24-160
|
Pending
Results
|
FDNS
|
Underground
|
UGE-S-24-163
|
No Significant
Results
|
FDNS
|
Underground
|
UGE-S-24-164
|
Pending
Results
|
FDNS
|
Underground
|
UGE-S-24-167
|
0
|
4.0
|
4.0
|
6.71
|
6.35
|
FDNS
|
Underground
|
UGE-S-24-167
|
14.6
|
20.9
|
6.3
|
11.03
|
9.61
|
UGE-S-24-167
|
169.4
|
174.2
|
4.8
|
4.12
|
12.34
|
UGE-S-24-167
|
186.8
|
192.9
|
6.1
|
8.52
|
21.31
|
UGE-S-24-170
|
63.75
|
68.7
|
4.95
|
5.12
|
1.45
|
FDNS
|
Underground
|
UGE-S-24-171
|
Pending
Results
|
FDNS
|
Underground
|
UGE-S-24-174
|
4.6
|
30.8
|
26.2
|
9.02
|
37.27
|
FDNS
|
Underground
|
Including
|
4.6
|
16.7
|
12.1
|
16.20
|
73.14
|
UGE-S-24-174
|
46.4
|
50.4
|
4.0
|
7.25
|
4.71
|
UGE-S-24-175
|
19.35
|
57.3
|
37.95
|
15.26
|
14.38
|
FDNS
|
Underground
|
Including
|
27.9
|
32.2
|
4.3
|
22.02
|
22.66
|
Including
|
44.5
|
49.85
|
5.35
|
65.01
|
46.54
|
UGE-S-24-175
|
96.85
|
116.7
|
19.85
|
7.95
|
9.80
|
Including
|
96.85
|
102.4
|
5.55
|
20.90
|
14.17
|
UGE-S-24-176
|
95.25
|
99.5
|
4.25
|
6.81
|
10.78
|
FDNS
|
Underground
|
UGE-S-24-176
|
144.2
|
158.9
|
14.7
|
6.10
|
2.60
|
Including
|
144.8
|
149.2
|
4.4
|
12.27
|
3.60
|
UGE-S-24-180
|
Pending
Results
|
FDNS
|
Underground
|
UGE-S-24-184
|
Pending
Results
|
FDNS
|
Underground
|
UGE-S-24-185
|
Pending
Results
|
FDNS
|
Underground
|
UGE-S-24-191
|
Pending
Results
|
FDNS
|
Underground
|
UGE-S-24-192
|
Pending
Results
|
FDNS
|
Underground
|
UGE-S-24-196
|
Pending
Results
|
FDNS
|
Underground
|
UGE-S-24-199
|
Pending
Results
|
FDNS
|
Underground
|
Table 2: Drillhole assay results from the
conversion underground drilling program reported for thickness
versus grade intervals above 14 (m x g/t Au >14). Drill hole
intercepts are reported in drill core lengths and true
width
Hole
ID
|
From
(m)
|
To
(m)
|
Interval
(m)
|
True Width
(m)
|
Au
(g/t)
|
Ag
(g/t)
|
Target
|
Zone
|
FDN-C24-137
|
192.3
|
205
|
12.7
|
8.98
|
3.85
|
5.26
|
Northern
|
Underground
|
FDN-C24-137
|
220.85
|
225.6
|
4.75
|
3.36
|
5.33
|
6.97
|
FDN-C24-137
|
236.95
|
250.5
|
13.55
|
9.58
|
4.98
|
5.88
|
Including
|
246.05
|
250.5
|
4.45
|
3.15
|
9.55
|
10.22
|
FDN-C24-137
|
275.4
|
289.35
|
13.95
|
9.86
|
8.88
|
7.12
|
Including
|
275.4
|
281.3
|
5.9
|
4.17
|
18.43
|
11.21
|
FDN-C24-138
|
1.9
|
6.7
|
4.8
|
2.75
|
4.33
|
3.99
|
Northern
|
Underground
|
FDN-C24-138
|
19.1
|
26.15
|
7.05
|
4.04
|
4.68
|
4.90
|
FDN-C24-138
|
36.6
|
45.55
|
8.95
|
5.13
|
3.13
|
3.03
|
FDN-C24-139
|
0
|
10.2
|
10.2
|
5.10
|
3.65
|
3.92
|
Northern
|
Underground
|
Including
|
3.8
|
7.4
|
3.6
|
1.80
|
6.86
|
5.88
|
FDN-C24-139
|
24.3
|
28.3
|
4
|
2.00
|
5.59
|
6.10
|
FDN-C24-139
|
36.1
|
43.7
|
7.6
|
3.80
|
6.04
|
5.78
|
FDN-C24-140
|
143.5
|
224.4
|
80.9
|
61.97
|
8.28
|
10.59
|
Northern
|
Underground
|
Including
|
167.8
|
177.05
|
9.25
|
7.09
|
31.29
|
33.55
|
Including
|
199.8
|
203.55
|
3.75
|
2.87
|
15.50
|
24.99
|
FDN-C24-141
|
0
|
4.4
|
4.4
|
3.81
|
9.47
|
16.09
|
Northern
|
Underground
|
FDN-C24-141
|
28
|
40
|
12
|
10.39
|
1.09
|
10.65
|
FDN-C24-141
|
69.7
|
76
|
6.3
|
5.46
|
2.25
|
17.44
|
FDN-C24-142
|
80.2
|
99.4
|
19.2
|
12.85
|
3.26
|
27.12
|
Northern
|
Underground
|
Including
|
87.65
|
90.35
|
2.7
|
1.81
|
6.64
|
28.73
|
Including
|
95.2
|
99.4
|
4.2
|
2.81
|
5.11
|
34.08
|
FDN-C24-143
|
72.05
|
90.6
|
18.55
|
12.41
|
1.27
|
10.99
|
Northern
|
Underground
|
Including
|
99.1
|
103
|
3.9
|
2.61
|
1.67
|
14.96
|
Including
|
112.2
|
122.6
|
10.4
|
6.96
|
3.00
|
27.57
|
FDN-C24-144
|
8.05
|
11.55
|
3.5
|
3.25
|
3.10
|
4.74
|
Northern
|
Underground
|
FDN-C24-144
|
19.25
|
23.6
|
4.35
|
4.03
|
3.72
|
3.88
|
FDN-C24-144
|
47.4
|
60
|
12.6
|
11.68
|
4.37
|
6.15
|
Including
|
54
|
59
|
5
|
4.64
|
8.26
|
8.04
|
FDN-C24-145
|
35.2
|
39.2
|
4
|
2.57
|
1.28
|
9.53
|
Northern
|
Underground
|
FDN-C24-145
|
51
|
56.7
|
5.7
|
3.66
|
1.29
|
13.80
|
FDN-C24-145
|
73
|
77.05
|
4.05
|
2.60
|
2.51
|
65.78
|
FDN-C24-145
|
94.4
|
105.7
|
11.3
|
7.26
|
1.79
|
12.40
|
FDN-C24-146
|
26.15
|
31.8
|
5.65
|
5.60
|
12.89
|
27.71
|
Northern
|
Underground
|
FDN-C24-146
|
65.3
|
75
|
9.7
|
9.61
|
7.57
|
18.09
|
FDN-C24-147
|
0
|
55.7
|
55.7
|
51.27
|
5.42
|
4.88
|
Northern
|
Underground
|
Including
|
0
|
7.8
|
7.8
|
7.18
|
15.49
|
10.88
|
Including
|
41.5
|
47.8
|
6.3
|
5.80
|
9.66
|
7.44
|
FDN-C24-148
|
97.05
|
103.4
|
6.35
|
4.08
|
4.39
|
30.72
|
Northern
|
Underground
|
FDN-C24-149
|
38.3
|
43.25
|
4.95
|
2.84
|
4.02
|
9.73
|
Northern
|
Underground
|
FDN-C24-149
|
96.3
|
100.7
|
4.4
|
2.83
|
4.06
|
38.04
|
FDN-C24-150
|
32.6
|
36.15
|
3.55
|
2.09
|
3.49
|
4.22
|
Northern
|
Underground
|
FDN-C24-150
|
48
|
61.6
|
13.6
|
7.99
|
5.88
|
5.86
|
Including
|
49.95
|
56.3
|
6.35
|
3.73
|
9.74
|
8.95
|
FDN-C24-151
|
16.4
|
23
|
6.6
|
5.72
|
5.35
|
11.16
|
Northern
|
Underground
|
FDN-C24-151
|
90.7
|
95
|
4.3
|
3.61
|
4.99
|
6.11
|
FDN-C24-152
|
70.35
|
74
|
3.65
|
2.63
|
4.34
|
82.37
|
Northern
|
Underground
|
FDN-C24-152
|
111.1
|
117.8
|
6.7
|
3.35
|
8.48
|
54.84
|
FDN-C24-152
|
130.7
|
135.45
|
4.75
|
3.05
|
6.74
|
21.90
|
FDN-C24-153
|
18.5
|
29.4
|
10.9
|
7.01
|
18.75
|
51.88
|
Northern
|
Underground
|
Including
|
21.5
|
27.9
|
6.4
|
4.11
|
30.32
|
79.59
|
FDN-C24-153
|
128.8
|
139.1
|
10.3
|
6.62
|
3.57
|
125.04
|
Including
|
129.65
|
132.7
|
3.05
|
1.96
|
8.23
|
318.62
|
FDN-C24-154
|
No Significant
Results
|
Northern
|
Underground
|
FDN-C24-155
|
56.6
|
80
|
23.4
|
23.31
|
5.34
|
5.29
|
Northern
|
Underground
|
Including
|
56.6
|
61.05
|
4.45
|
4.09
|
10.88
|
8.89
|
Including
|
72.8
|
76.5
|
3.7
|
3.69
|
9.53
|
8.43
|
FDN-C24-156
|
28.4
|
61.9
|
33.5
|
33.5
|
6.09
|
8.03
|
Northern
|
Underground
|
Including
|
28.9
|
40.7
|
11.8
|
11.8
|
9.24
|
9.29
|
FDN-C24-157
|
5
|
51.5
|
46.5
|
45.8
|
7.00
|
12.75
|
Northern
|
Underground
|
Including
|
5
|
9.1
|
4.1
|
4.04
|
7.79
|
9.38
|
Including
|
19.1
|
27.65
|
8.55
|
8.42
|
5.89
|
11.48
|
Including
|
31.85
|
42.2
|
10.35
|
10.19
|
20.17
|
30.11
|
FDN-C24-158
|
16.8
|
24.35
|
7.55
|
7.18
|
5.73
|
68.16
|
Northern
|
Underground
|
FDN-C24-158
|
71.1
|
80.2
|
9.1
|
8.65
|
4.43
|
3.80
|
FDN-C24-158
|
94.1
|
98.9
|
4.8
|
4.57
|
3.98
|
3.52
|
FDN-C24-159
|
18.9
|
23.9
|
5
|
4.92
|
5.11
|
49.76
|
Northern
|
Underground
|
FDN-C24-159
|
44.1
|
52.7
|
8.6
|
8.31
|
3.59
|
8.90
|
FDN-C24-160
|
62.4
|
67.15
|
4.75
|
2.72
|
15.51
|
38.41
|
Northern
|
Underground
|
FDN-C24-161
|
No Significant
Results
|
Northern
|
Underground
|
FDN-C24-162
|
68.6
|
73.05
|
4.45
|
1.88
|
24.06
|
55.62
|
Northern
|
Underground
|
Including
|
70.5
|
71.85
|
1.35
|
0.57
|
77.84
|
106.01
|
FDN-C24-163
|
70.55
|
83.3
|
12.75
|
6.76
|
14.05
|
46.73
|
Northern
|
Underground
|
Including
|
79.2
|
83.3
|
4.1
|
2.17
|
23.80
|
44.21
|
FDN-C24-163
|
92.65
|
104.25
|
11.6
|
5.8
|
6.66
|
26.58
|
FDN-C24-164
|
68.3
|
72.1
|
3.8
|
2.44
|
7.33
|
60.31
|
Northern
|
Underground
|
FDN-C24-165
|
63.4
|
69
|
5.6
|
4.59
|
5.08
|
33.63
|
Northern
|
Underground
|
FDN-C24-166
|
51.25
|
56.2
|
4.95
|
4.93
|
23.26
|
55.50
|
Northern
|
Underground
|
FDN-C24-166
|
75.9
|
88.9
|
13
|
12.95
|
6.49
|
5.19
|
Including
|
84.7
|
88.9
|
4.2
|
4.18
|
10.91
|
6.00
|
FDN-C24-167
|
62
|
68.45
|
6.45
|
5.85
|
11.27
|
17.16
|
Northern
|
Underground
|
Including
|
63.5
|
67.45
|
3.95
|
3.58
|
16.33
|
18.95
|
FDN-C24-168
|
82.5
|
87.1
|
4.6
|
2.97
|
12.19
|
84.86
|
Northern
|
Underground
|
FDN-C24-169
|
107.4
|
111.7
|
4.3
|
2.15
|
4.99
|
10.62
|
Northern
|
Underground
|
FDN-C24-169
|
129.8
|
133.95
|
4.15
|
2.08
|
7.58
|
20.16
|
FDN-C24-169
|
166.85
|
171.1
|
4.25
|
2.13
|
6.27
|
18.31
|
FDN-C24-170
|
0
|
18.15
|
18.15
|
10.41
|
17.46
|
25.21
|
Northern
|
Underground
|
FDN-C24-170
|
59.8
|
64.5
|
4.7
|
2.7
|
6.78
|
67.92
|
FDN-C24-171
|
5.4
|
14.5
|
9.1
|
7.88
|
8.24
|
7.99
|
Northern
|
Underground
|
FDN-C24-171
|
31.55
|
39.8
|
8.25
|
7.14
|
10.16
|
8.25
|
FDN-C24-172
|
18.35
|
23.1
|
4.75
|
4.73
|
9.23
|
17.93
|
Northern
|
Underground
|
FDN-C24-173
|
Pending
Results
|
Northern
|
Underground
|
FDN-C24-174
|
35.85
|
48.8
|
12.95
|
12.9
|
6.27
|
6.54
|
Northern
|
Underground
|
FDN-C24-175
|
27.9
|
32.5
|
4.6
|
4.32
|
9.32
|
9.78
|
Northern
|
Underground
|
FDN-C24-175
|
37.3
|
41.4
|
4.1
|
3.85
|
5.72
|
7.68
|
Northern
|
Underground
|
FDN-C24-175
|
48.7
|
54.55
|
5.85
|
5.5
|
10.10
|
11.16
|
Northern
|
Underground
|
FDN-C24-176
|
30.3
|
36.3
|
6
|
5.2
|
8.82
|
6.08
|
Northern
|
Underground
|
FDN-C24-177
|
Pending
Results
|
Northern
|
Underground
|
FDN-C24-178
|
Pending
Results
|
Northern
|
Underground
|
FDN-C24-179
|
Pending
Results
|
Northern
|
Underground
|
FDN-C24-180
|
Pending
Results
|
Northern
|
Underground
|
FDN-C24-181
|
Pending
Results
|
Northern
|
Underground
|
FDN-C24-182
|
Pending
Results
|
Northern
|
Underground
|
FDN-C24-183
|
Pending
Results
|
Northern
|
Underground
|
FDN-C24-184
|
Pending
Results
|
Northern
|
Underground
|
FDN-C24-185
|
Pending
Results
|
Northern
|
Underground
|
FDN-C24-186
|
Pending
Results
|
Northern
|
Underground
|
FDN-C24-187
|
Pending
Results
|
Northern
|
Underground
|
FDN-C24-188
|
Pending
Results
|
Northern
|
Underground
|
FDN-C24-189
|
Pending
Results
|
Northern
|
Underground
|
Table 3: Collar locations of reported drill
holes
Hole
ID
|
Target
|
Easting
|
Northing
|
Elevation
|
Azimuth
|
Dip
|
EOH
(m)
|
Drilling
Type
|
Year
|
UGE-S-24-150
|
FDNS
|
778181
|
9582366
|
1184
|
345
|
20
|
163.10
|
Underground
|
2024
|
UGE-S-24-152
|
FDNS
|
778178
|
9582354
|
1184
|
298
|
20
|
140.00
|
Underground
|
2024
|
UGE-S-24-153
|
FDNS
|
778196
|
9582232
|
1184
|
285
|
-26
|
230.00
|
Underground
|
2024
|
UGE-S-24-155
|
FDNS
|
778197
|
9582233
|
1185
|
268
|
-4
|
215.40
|
Underground
|
2024
|
UGE-S-24-158
|
FDNS
|
778197
|
9582235
|
1185
|
300
|
-20
|
220.00
|
Underground
|
2024
|
UGE-S-24-159
|
FDNS
|
778197
|
9582234
|
1185
|
298
|
-7
|
250.30
|
Underground
|
2024
|
UGE-S-24-160
|
FDNS
|
778197
|
9582234
|
1185
|
323
|
-5
|
210.00
|
Underground
|
2024
|
UGE-S-24-163
|
FDNS
|
778202
|
9582150
|
1191
|
127
|
-25
|
257.70
|
Underground
|
2024
|
UGE-S-24-164
|
FDNS
|
778221
|
9582229
|
1186
|
152
|
20
|
210.90
|
Underground
|
2024
|
UGE-S-24-167
|
FDNS
|
778222
|
9582229
|
1186
|
127
|
4
|
209.90
|
Underground
|
2024
|
UGE-S-24-170
|
FDNS
|
778197
|
9582211
|
1185
|
239
|
-10
|
270.00
|
Underground
|
2024
|
UGE-S-24-171
|
FDNS
|
778222
|
9582231
|
1187
|
112
|
35
|
200.00
|
Underground
|
2024
|
UGE-S-24-174
|
FDNS
|
778222
|
9582232
|
1186
|
84
|
20
|
155.00
|
Underground
|
2024
|
UGE-S-24-175
|
FDNS
|
778202
|
9582346
|
1182
|
150
|
-13
|
199.00
|
Underground
|
2024
|
UGE-S-24-176
|
FDNS
|
778197
|
9582213
|
1185
|
250
|
-5
|
226.00
|
Underground
|
2024
|
UGE-S-24-180
|
FDNS
|
778202
|
9582346
|
1182
|
120
|
-20
|
203.00
|
Underground
|
2024
|
UGE-S-24-184
|
FDNS
|
778202
|
9582347
|
1182
|
71
|
-20
|
181.60
|
Underground
|
2024
|
UGE-S-24-185
|
FDNS
|
778202
|
9582522
|
1178
|
118
|
-30
|
173.90
|
Underground
|
2024
|
UGE-S-24-191
|
FDNS
|
778199
|
9582797
|
1180
|
101
|
-30
|
220.00
|
Underground
|
2024
|
UGE-S-24-192
|
FDNS
|
778199
|
9582797
|
1081
|
130
|
-10
|
248.00
|
Underground
|
2024
|
UGE-S-24-196
|
FDNS
|
778199
|
9582556
|
1085
|
60
|
-35
|
197.70
|
Underground
|
2024
|
UGE-S-24-199
|
FDNS
|
778199
|
9582552
|
1087
|
155
|
25
|
300.00
|
Underground
|
2024
|
FDN-C24-149
|
FDN -
Conversion
|
778072
|
9583219
|
1025
|
280
|
-53
|
130.0
|
Underground
|
2024
|
FDN-C24-151
|
FDN -
Conversion
|
778118
|
9583349
|
1053
|
160
|
-32
|
95.0
|
Underground
|
2024
|
FDN-C24-152
|
FDN -
Conversion
|
778093
|
9583022
|
1026
|
270
|
-48
|
146.0
|
Underground
|
2024
|
FDN-C24-153
|
FDN -
Conversion
|
778093
|
9583022
|
1026
|
248
|
-50
|
170.0
|
Underground
|
2024
|
FDN-C24-154
|
FDN -
Conversion
|
778092
|
9583023
|
1026
|
282
|
-50
|
167.4
|
Underground
|
2024
|
FDN-C24-155
|
FDN -
Conversion
|
778135
|
9583356
|
1079
|
315
|
-7
|
80.0
|
Underground
|
2024
|
FDN-C24-156
|
FDN -
Conversion
|
778135
|
9583356
|
1079
|
295
|
15
|
62.8
|
Underground
|
2024
|
FDN-C24-157
|
FDN -
Conversion
|
778119
|
9583274
|
1077
|
247
|
-10
|
90.0
|
Underground
|
2024
|
FDN-C24-158
|
FDN -
Conversion
|
778090
|
9582823
|
1248
|
267
|
-7
|
120.0
|
Underground
|
2024
|
FDN-C24-159
|
FDN -
Conversion
|
778114
|
9582820
|
1248
|
230
|
15
|
80.0
|
Underground
|
2024
|
FDN-C24-160
|
FDN -
Conversion
|
778075
|
9583084
|
1024
|
302
|
-53
|
166.0
|
Underground
|
2024
|
FDN-C24-161
|
FDN -
Conversion
|
778078
|
9583280
|
1026
|
319
|
-59
|
120.0
|
Underground
|
2024
|
FDN-C24-162
|
FDN -
Conversion
|
778069
|
9583279
|
1026
|
294
|
-67
|
124.5
|
Underground
|
2024
|
FDN-C24-163
|
FDN -
Conversion
|
778069
|
9583277
|
1026
|
256
|
-64
|
120.0
|
Underground
|
2024
|
FDN-C24-164
|
FDN -
Conversion
|
778069
|
9583278
|
1026
|
273
|
-57
|
96.0
|
Underground
|
2024
|
FDN-C24-165
|
FDN -
Conversion
|
778070
|
9583277
|
1025
|
250
|
-37
|
88.0
|
Underground
|
2024
|
FDN-C24-166
|
FDN -
Conversion
|
778114
|
9582820
|
1248
|
211
|
3
|
90.0
|
Underground
|
2024
|
FDN-C24-167
|
FDN -
Conversion
|
778096
|
9583225
|
1027
|
265
|
26
|
82.0
|
Underground
|
2024
|
FDN-C24-168
|
FDN -
Conversion
|
778096
|
9583223
|
1024
|
312
|
-45
|
145.3
|
Underground
|
2024
|
FDN-C24-169
|
FDN -
Conversion
|
778137
|
9583281
|
1076
|
297
|
-59
|
218.4
|
Underground
|
2024
|
FDN-C24-170
|
FDN -
Conversion
|
778114
|
9583008
|
1076
|
268
|
-56
|
224.2
|
Underground
|
2024
|
FDN-C24-171
|
FDN -
Conversion
|
778079
|
9583380
|
1054
|
129
|
-30
|
70.0
|
Underground
|
2024
|
FDN-C24-172
|
FDN -
Conversion
|
778117
|
9583348
|
1054
|
140
|
-3
|
55.3
|
Underground
|
2024
|
FDN-C24-173
|
FDN -
Conversion
|
778131
|
9583356
|
1105
|
300
|
35
|
60.0
|
Underground
|
2024
|
FDN-C24-174
|
FDN -
Conversion
|
778131
|
9583356
|
1104
|
300
|
5
|
50.0
|
Underground
|
2024
|
FDN-C24-175
|
FDN -
Conversion
|
778131
|
9583356
|
1103
|
300
|
-35
|
60.0
|
Underground
|
2024
|
FDN-C24-176
|
FDN -
Conversion
|
778128
|
9583351
|
1103
|
244
|
-33
|
67.0
|
Underground
|
2024
|
FDN-C24-177
|
FDN -
Conversion
|
778146
|
9583281
|
1101
|
322
|
-26
|
45.0
|
Underground
|
2024
|
FDN-C24-178
|
FDN -
Conversion
|
778116
|
9583346
|
1221
|
302
|
0
|
44.7
|
Underground
|
2024
|
FDN-C24-179
|
FDN -
Conversion
|
778104
|
9583355
|
1128
|
309
|
-47
|
35.3
|
Underground
|
2024
|
FDN-C24-180
|
FDN -
Conversion
|
778114
|
9582819
|
1248
|
200
|
8
|
135.0
|
Underground
|
2024
|
FDN-C24-181
|
FDN -
Conversion
|
778114
|
9582820
|
1248
|
211
|
16
|
90.0
|
Underground
|
2024
|
FDN-C24-182
|
FDN -
Conversion
|
778140
|
9583281
|
1127
|
323
|
-23
|
50.0
|
Underground
|
2024
|
FDN-C24-183
|
FDN -
Conversion
|
778111
|
9583281
|
1152
|
325
|
-38
|
55.0
|
Underground
|
2024
|
FDN-C24-184
|
FDN -
Conversion
|
778111
|
9583346
|
1170
|
305
|
-45
|
55.0
|
Underground
|
2024
|
FDN-C24-185
|
FDN -
Conversion
|
778085
|
9583055
|
1270
|
173
|
30
|
65.0
|
Underground
|
2024
|
FDN-C24-186
|
FDN -
Conversion
|
778085
|
9583055
|
1269
|
160
|
15
|
120.0
|
Underground
|
2024
|
FDN-C24-187
|
FDN -
Conversion
|
778085
|
9583055
|
1269
|
100
|
20
|
65.0
|
Underground
|
2024
|
FDN-C24-188
|
FDN -
Conversion
|
778083
|
9583064
|
1269
|
320
|
17
|
90.0
|
Underground
|
2024
|
FDN-C24-189
|
FDN -
Conversion
|
778083
|
9583064
|
1269
|
340
|
17
|
155.5
|
Underground
|
2024
|
SOURCE Lundin Gold Inc.